<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Timeless Medical Nutrition Platform™ &#8211; Timeless Medical Systems</title>
	<atom:link href="https://www.timelessmedical.com/portfolio-category/tmnp-research/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.timelessmedical.com</link>
	<description></description>
	<lastBuildDate>Tue, 18 Feb 2025 16:51:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.timelessmedical.com/wp-content/uploads/2023/03/timelessmedical-favicon-150x150.png</url>
	<title>Timeless Medical Nutrition Platform™ &#8211; Timeless Medical Systems</title>
	<link>https://www.timelessmedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Improving Administration and Documentation of Enteral Nutrition Support Therapy in a Veteran Affairs Health Care System: Use of Medication Administration Record and Bar Code Scanning Technology</title>
		<link>https://www.timelessmedical.com/portfolio/best-practices-for-handling-and-administration-of-expressed-human-milk-and-donor-human-milk-for-hospitalized-preterm-infants-2-2-2-2-2-2-2-3/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 07 Sep 2023 19:26:15 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15411</guid>

					<description><![CDATA[Improving Administration and Documentation of Enteral Nutrition Support Therapy in a Veteran Affairs Health Care System: Use of Medication Administration Record and Bar Code Scanning Technology The goal of this study was to evaluate and improve the ordering, administration, documentation, and monitoring of enteral nutrition within an adult inpatient setting.  The authors noted that documentation [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15411" class="elementor elementor-15411" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Improving Administration and Documentation of Enteral Nutrition Support Therapy in a Veteran Affairs Health Care System: Use of Medication Administration Record and Bar Code Scanning Technology</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p>The goal of this study was to evaluate and improve the ordering, administration, documentation, and monitoring of enteral nutrition within an adult inpatient setting.  The authors noted that documentation improved significantly with the implementation of bar code scanning for enteral feedings within their organization.  They noted that use of scanning could prevent formula misadministration and ensure optimal delivery as a strategy to prevent malnutrition.</p><p> </p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Journal of Patient Safety</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2023</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Chew, Mary M.; Rivas, Salvador; Chesser, Michael; Landas, Noel; Schaefer, Stephanie; Enright, Amy; Olsen, Jamie; Meacci, Katie; Luevano, Victor; Harraway, Doristeen; Citty, Sandra W.
</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://journals.lww.com/advancesinneonatalcare/Abstract/2019/02000/Evaluation_of_Key_Factors_Impacting_Feeding_Safety.5.aspx" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Evaluation of Key Factors Impacting Feeding Safety in the Neonatal Intensive Care Unit​</title>
		<link>https://www.timelessmedical.com/portfolio/best-practices-for-handling-and-administration-of-expressed-human-milk-and-donor-human-milk-for-hospitalized-preterm-infants-2-2-2-2-2-2-2-2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 07 Sep 2023 19:23:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15406</guid>

					<description><![CDATA[Evaluation of Key Factors Impacting Feeding Safety in the Neonatal Intensive Care Unit This systematic review article evaluates current literature and provides recommendations on best practices for feeding safety in the neonatal intensive care unit.  Recommendations include use of a centralized preparation area with dedicated technicians for handling human milk and formula, bar code scanning [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15406" class="elementor elementor-15406" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Evaluation of Key Factors Impacting Feeding Safety in the Neonatal Intensive Care Unit</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p>This systematic review article evaluates current literature and provides recommendations on best practices for feeding safety in the neonatal intensive care unit.  Recommendations include use of a centralized preparation area with dedicated technicians for handling human milk and formula, bar code scanning technology, and support from a registered dietitian.  </p><p> </p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Advances in Neonatal Care</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2019</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Matus, Bethany A.; Bridges, Kayla M.; Logomarsino, John V.</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://journals.lww.com/advancesinneonatalcare/Abstract/2019/02000/Evaluation_of_Key_Factors_Impacting_Feeding_Safety.5.aspx" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Standards for Levels of Neonatal Care: II, III, and IV</title>
		<link>https://www.timelessmedical.com/portfolio/best-practices-for-handling-and-administration-of-expressed-human-milk-and-donor-human-milk-for-hospitalized-preterm-infants-2-2-2-2-2-2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 07 Sep 2023 19:19:51 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15401</guid>

					<description><![CDATA[Standards for Levels of Neonatal Care: II, III, and IV These 2023 standards published by the American Academy of Pediatrics outline best practices within the various levels of neonatal care.  Among the many recommendations, nutrition and lactation support are promoted including the recommendation that the facility will utilize a dedicated space away from the bedside [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15401" class="elementor elementor-15401" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Standards for Levels of Neonatal Care: II, III, and IV</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p>These 2023 standards published by the American Academy of Pediatrics outline best practices within the various levels of neonatal care.  Among the many recommendations, nutrition and lactation support are promoted including the recommendation that the facility will utilize a dedicated space away from the bedside for feeding preparation, develop standardized feeding protocols, and have procedures in place for accurate verification of human milk AND formula to avoid misappropriation.</p><p> </p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">American Academy of Pediatrics</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2023</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Ann R. Stark, DeWayne M. Pursley, Lu-Ann Papile, Eric C. Eichenwald, Charles T. Hankins, Rosanne K. Buck, Tamara J. Wallace, Patricia G. Bondurant, Nicole E. Faster</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://publications.aap.org/pediatrics/article/151/6/e2023061957/191305/Standards-for-Levels-of-Neonatal-Care-II-III-and" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Enhancing Children&#8217;s Safety by Barcoding Implementation at Breast Milk Feeding​</title>
		<link>https://www.timelessmedical.com/portfolio/best-practices-for-handling-and-administration-of-expressed-human-milk-and-donor-human-milk-for-hospitalized-preterm-infants-2-2-2-2-2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 07 Sep 2023 19:17:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15396</guid>

					<description><![CDATA[Enhancing Children&#8217;s Safety by Barcoding Implementation at Breast Milk Feeding In this study, the authors review the former process of  handling and administering human milk within their hospital followed by the steps taken to implement bar code scanning of human milk at their institution.   “Barcoding technology has the ability to accurately verify patient identity and [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15396" class="elementor elementor-15396" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Enhancing Children's Safety by Barcoding Implementation at Breast Milk Feeding</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p>In this study, the authors review the former process of  handling and administering human milk within their hospital followed by the steps taken to implement bar code scanning of human milk at their institution.  </p><p>“Barcoding technology has the ability to accurately verify patient identity and prescription accuracy before milk administration.”</p><p> </p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">IOS Press</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2017</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Mariana Daus, Thelma Maydana, Daniel Rizzato Lede, Daniel Luna</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://ebooks.iospress.nl/publication/48103" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Best Practices for Handling and Administration of Expressed Human Milk and Donor Human Milk for Hospitalized Preterm Infants</title>
		<link>https://www.timelessmedical.com/portfolio/best-practices-for-handling-and-administration-of-expressed-human-milk-and-donor-human-milk-for-hospitalized-preterm-infants/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 23 Mar 2023 15:51:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15087</guid>

					<description><![CDATA[Best Practices for Handling and Administration of Expressed Human Milk and Donor Human Milk for Hospitalized Preterm Infants Human milk in the health care setting, particularly the neonatal intensive care unit, is often viewed as “medicine” or an adjunct therapy. Some of the most fragile patients are those premature or critically ill infants receiving human [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15087" class="elementor elementor-15087" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Best Practices for Handling and Administration of Expressed Human Milk and Donor Human Milk for Hospitalized Preterm Infants
</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p class="mb0">Human milk in the health care setting, particularly the neonatal intensive care unit, is often viewed as “medicine” or an adjunct therapy. Some of the most fragile patients are those premature or critically ill infants receiving human milk feedings. Therefore, every precaution must be taken with human milk handling to ensure safety. Aseptic technique with proper sanitation and holding times/temperatures to limit microbial growth; use of technology to prevent misadministration of human milk and fortification errors as well as for tracking of expiration dates/times and lot numbers; and workflow strategies to promote safety while improving efficiencies are worthy endeavors of all facilities.</p><p><a id="h10" name="h10" class="reset-hash-position"></a></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Frontiers Nutrition: Clinical Nutrition</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2018</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Caroline Steele</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://www.frontiersin.org/articles/10.3389/fnut.2018.00076/full" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Centralized Infant Formula Preparation Room in the Neonatal Intensive Care Unit Reduces Incidence of Microbial Contamination</title>
		<link>https://www.timelessmedical.com/portfolio/centralized-infant-formula-preparation-room-in-the-neonatal-intensive-care-unit-reduces-incidence-of-microbial-contamination/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 23 Mar 2023 15:46:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.timelessmedical.com/?post_type=portfolio&#038;p=15082</guid>

					<description><![CDATA[Centralized Infant Formula Preparation Room in the Neonatal Intensive Care Unit Reduces Incidence of Microbial Contamination Increasing concern regarding potential pathogens in infant formulas led to this evaluation of the influence of procedural and environmental factors on infant formula contamination. In two phases of study, a total of 526 formula samples were analyzed for contamination. [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="15082" class="elementor elementor-15082" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6649589 elementor-widget elementor-widget-spacer" data-id="6649589" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
					<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6b7f2d1 elementor-widget elementor-widget-heading" data-id="6b7f2d1" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Centralized Infant Formula Preparation Room in the Neonatal Intensive Care Unit Reduces Incidence of Microbial Contamination</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p><span style="color: #505050; font-family: helvetica, sans-serif;">Increasing concern regarding potential pathogens in infant formulas led to this evaluation of the influence of procedural and environmental factors on infant formula contamination. In two phases of study, a total of 526 formula samples were analyzed for contamination.</span></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Journal Of The Academy Of Nutrition And Dietetics</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2008</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Author</span><div class="gt3_meta_value type_custom">Caroline Steele, MS, RD, CSP;
Robert Short, PhD</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-d711069 elementor-widget elementor-widget-gt3-core-button" data-id="d711069" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://www.jandonline.org/article/S0002-8223%2808%2901406-5/fulltext#articleInformation" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--d711069">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safe Handling of Human Milk Within the Hospital Setting</title>
		<link>https://www.timelessmedical.com/portfolio/safe-handling/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 22:55:12 +0000</pubDate>
				<guid isPermaLink="false">https://tms.mppdev.net/?post_type=portfolio&#038;p=13488</guid>

					<description><![CDATA[Safe Handling of Human Milk Within the Hospital Setting This study examined critical steps taken for patient safety throughout the feeding process with emphasis on three primary areas: avoiding microbial contamination, preventing misadministration (wrong HM administered), and ensuring preparation accuracy. “Research has shown that scanning systems (depending on specific product features) may reduce other errors [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="13488" class="elementor elementor-13488" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-2ec9451 elementor-widget elementor-widget-heading" data-id="2ec9451" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Safe Handling of Human Milk Within the Hospital Setting</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p><span style="font-weight: 400;">This study examined</span><span style="font-weight: 400;"> critical steps taken for patient safety throughout the feeding process with emphasis on three primary areas: avoiding microbial contamination, preventing misadministration (wrong HM administered), and ensuring preparation accuracy.</span></p><p><span style="font-weight: 400;">“Research has shown that scanning systems (depending on specific product features) may reduce other errors and improve efficiencies by preventing fortifier/additive misadministration, monitoring expiration dates/times of prepared feedings as well as stored HM and fortifiers/additives, tracking lot numbers of DHM and fortifiers, automatically calculating fortified feeding recipes, reducing staff time needed for two-person verification, lot tracking, and recipe calculation.”</span></p><p><span style="font-weight: 400;">The Timeless Medical Nutrition Platform™</span><span style="font-weight: 400;">  </span><span style="font-weight: 400;">is the most comprehensive feeding solution on the market. With seamless electronic health record integration, the program tracks and traces expressed breastmik, human donor milk and formula throughout the entire feed process. </span><span style="font-weight: 400;"> </span></p><p><i>The following study was conducted independently at a facility utilizing the <span style="font-weight: 400;">Timeless Medical Nutrition Platform™</span> with no financial incentive provided by Timeless Medical Systems</i></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Neonatal Intensive Care</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2020</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Authors</span><div class="gt3_meta_value type_custom">Steele, C</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-249f6b8 elementor-widget elementor-widget-gt3-core-button" data-id="249f6b8" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://nicmag.ca/pdf/NIC-33-3-Summer-2020-R23-web.pdf" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--249f6b8">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Does Feeding Previously Frozen (Thawed) Fortified Human Milk Increase the Incidence of Lactobezoar (Milk Curd) Obstruction?</title>
		<link>https://www.timelessmedical.com/portfolio/freezing/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 22:49:31 +0000</pubDate>
				<guid isPermaLink="false">https://tms.mppdev.net/?post_type=portfolio&#038;p=13480</guid>

					<description><![CDATA[This retrospective study examined the incidence of milk curd obstruction in thawed fortified Human Milk. At the time of feeding, the nurse scanned the patient armband and the bar code label on the prepared feeding to confirm patient identity and ensure the feeding has not expired. With the initiation of scanning fortifiers and additives in [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="13480" class="elementor elementor-13480" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-5f567fb elementor-widget elementor-widget-heading" data-id="5f567fb" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Does Feeding Previously Frozen (Thawed) Fortified Human Milk Increase the Incidence of Lactobezoar (Milk Curd) Obstruction?</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p><span style="font-weight: 400;">This retrospective study examined the incidence of milk curd obstruction in thawed fortified Human Milk. At the time of feeding, the nurse scanned the patient armband and the bar code label on the prepared feeding to confirm patient identity and ensure the feeding has not expired. With the initiation of scanning fortifiers and additives in 2018, 2 full years of feeding data were available to evaluate the storage and feeding times of fortified HM.</span></p><p><em>“The scanning system allows for the monitoring of HM and all enteral products including tracking of inventory, lot numbers, and expiration dates as well as provides a record of when a feeding was given.”</em></p><p>The Timeless Medical Women &amp; Infants System<span>™</span> is the number one software used by hospitals in North America and around the globe. It supports improved outcomes for patients through product management including lot scanning, product recall preparedness, fortifier and formula scanning.</p><p><i>The following study was conducted independently at a facility utilizing the Timeless Women &amp; Infants System™ with no financial incentive provided by Timeless Medical Systems</i></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Journal of the Academy of Nutrition and Dietetics</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2021</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Authors</span><div class="gt3_meta_value type_custom">Steele, C., and Bixby C</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-cb01c8d elementor-widget elementor-widget-gt3-core-button" data-id="cb01c8d" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://www.jandonline.org/article/S2212-2672%2821%2900029-0/fulltext" target="_blank">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--cb01c8d">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Breast Milk Bar Code Scanning Results in Time Savings and Staff Efficiency</title>
		<link>https://www.timelessmedical.com/portfolio/bm-barcode-scanning/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 22:44:50 +0000</pubDate>
				<guid isPermaLink="false">https://tms.mppdev.net/?post_type=portfolio&#038;p=13473</guid>

					<description><![CDATA[Breast Milk Bar Code Scanning Results in Time Savings and Staff Efficiency This study supports barcode scanning to improve patient safety while saving significant time in the preparation and feeding process. “Bar-code scanning resulted in a statistically significant reduction in Nutrition Lab staff time spent directly handling breast milk. The resulting total time savings is [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="13473" class="elementor elementor-13473" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-5228736 elementor-widget elementor-widget-heading" data-id="5228736" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Breast Milk Bar Code Scanning Results in Time Savings and Staff Efficiency
</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p>This study supports barcode scanning to improve patient safety while saving significant time in the preparation and feeding process.</p><p><em><span style="font-weight: 400;">“Bar-code scanning resulted in a statistically significant reduction in Nutrition Lab staff time spent directly handling breast milk. The resulting total time savings is 2,380 hours per year for the organization, with 1,040 hours completely eliminated, for a cost savings and 1,340 hours available for other patient-care duties.”</span></em></p><p>The Timeless Medical Women &amp; Infants System<span>™</span> is clinically proven to reduce costs, and save clinicians time. It is the only system able to read and decode human milk bank barcodes, and all formula manufacturer barcodes, ensuring the right feed to the right patient every time.</p><p><i>The following study was conducted independently at a facility utilizing the Timeless Women &amp; Infants System™ with no financial incentive provided by Timeless Medical Systems</i></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Journal of the Academy of Nutrition and Dietetics</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2015</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Authors</span><div class="gt3_meta_value type_custom">Steele, C., Czerwin A., and Bixby C.</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-3d566bf elementor-widget elementor-widget-gt3-core-button" data-id="3d566bf" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://www.jandonline.org/article/S2212-2672%2814%2901050-8/fulltext">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--3d566bf">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Centralized Breastmilk Handling and Bar Code Scanning Improve Safety and Reduce Breastmilk Administration Errors</title>
		<link>https://www.timelessmedical.com/portfolio/centralized-bm-handling/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 15 Mar 2023 22:40:11 +0000</pubDate>
				<guid isPermaLink="false">https://tms.mppdev.net/?post_type=portfolio&#038;p=13466</guid>

					<description><![CDATA[Centralized Breastmilk Handling and Bar Code Scanning Improve Safety and Reduce Breastmilk Administration Errors This study supports the use of centralized breastmilk handling and systems for proper identification of breastmilk. “During the first 6 months of breastmilk bar code scanning, 55 attempts to feed the wrong breastmilk to the wrong patient and 127 attempts to [&#8230;]]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="13466" class="elementor elementor-13466" data-elementor-post-type="portfolio">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-a2cd0de elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="a2cd0de" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8adb5fa" data-id="8adb5fa" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-50fdd43 elementor-widget elementor-widget-heading" data-id="50fdd43" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
			<h1 class="elementor-heading-title elementor-size-default">Centralized Breastmilk Handling and Bar Code Scanning Improve Safety and Reduce Breastmilk Administration Errors</h1>		</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f0920e3 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f0920e3" data-element_type="section">
						<div class="elementor-container elementor-column-gap-extended">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fb7c00d" data-id="fb7c00d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fd7663e elementor-widget elementor-widget-text-editor" data-id="fd7663e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p><span style="font-weight: 400;">This study supports the use of centralized breastmilk handling and systems for proper identification of breastmilk.</span></p><p><em><span style="font-weight: 400;">“During the first 6 months of breastmilk bar code scanning, 55 attempts to feed the wrong breastmilk to the wrong patient and 127 attempts to feed expired breastmilk were prevented.”</span></em></p><p><span style="font-weight: 400;">The Timeless Medical Women &amp; Infants System</span><span style="font-weight: 400;">TM </span><span style="font-weight: 400;">is backed by evidence based research, ensuring the right milk goes to the right patient every time and empowering clinicians to prepare and feed confidently.</span></p><p><i>The following study was conducted independently at a facility utilizing the Timeless Women &amp; Infants System ™ with no financial incentive provided by Timeless Medical Systems</i></p>						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-cb8ca4f" data-id="cb8ca4f" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-67afbbc elementor-widget elementor-widget-gt3-core-custommeta" data-id="67afbbc" data-element_type="widget" data-widget_type="gt3-core-custommeta.default">
				<div class="elementor-widget-container">
			<div class="gt3_meta_values_wrapper vertical align_left"><div class="gt3_meta_values_item elementor-repeater-item-23b9ba2"><span class="gt3_meta_label_title">Publication</span><div class="gt3_meta_value type_custom">Breastfeeding Medicine</div></div><div class="gt3_meta_values_item elementor-repeater-item-829fca3"><span class="gt3_meta_label_title">Year</span><div class="gt3_meta_value type_custom">2014</div></div><div class="gt3_meta_values_item elementor-repeater-item-8831ba9"><span class="gt3_meta_label_title">Authors</span><div class="gt3_meta_value type_custom">Steele, C and Bixby, C.</div></div></div>		</div>
				</div>
				<div class="gt3-core-button--alignment_left elementor-element elementor-element-4ac2b93 elementor-widget elementor-widget-gt3-core-button" data-id="4ac2b93" data-element_type="widget" data-widget_type="gt3-core-button.default">
				<div class="elementor-widget-container">
				<div class="gt3_module_button_elementor size_normal alignment_left button_icon_none hover_none ">
		<a class="button_size_elementor_normal alignment_left border_icon_none hover_none btn_icon_position_left" href="https://www.liebertpub.com/doi/10.1089/bfm.2014.0077">
				<span class="gt3_module_button__container">
											<span class="gt3_module_button__cover front"><span class="elementor_gt3_btn_text">Go to Article</span></span>
															</span>
		</a>
	</div>

<script type="application/json" id="settings--4ac2b93">[]</script>		</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				</div>
		]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
